(12) Combination control consists of gasketed plastic enclosure, thermostat, contactor and optional control transformer. Transformer must be used on 480 volts and is recommended for 240 volts. To omit stepdown transformer, add "LT" to end of model number. See NR25 chart above for thermostat options. Additional control options available, consult factory.
FEP is a fluorinated ethylene propylene fluoropolymer.
(12) Combination control consists of gasketed plastic enclosure, thermostat, contactor and optional control transformer. Transformer must be used on 480 volts and is recommended for 240 volts. To omit stepdown transformer, add "LT" to end of model number. See DLC chart above for thermostat options. Additional control options available, consult factory.
FEP is a fluorinated ethylene propylene fluoropolymer.
Longer sensor lengths and higher temperature ranges available. Many features included as standard. 0-10V, 4-20MA and RS485 outputs optional, consult factory.
FEP is a fluorinated ethylene propylene fluoropolymer.
(12) Combination control consists of gasketed plastic enclosure, thermostat, contactor and optional control transformer. Transformer must be used on 480 volts and is recommended for 240 volts. To omit step- down transformer, add "LT" to end of model number. See DSL chart for thermostat options. Longer sensor lengths and additional control options available, consult factory.
FEP is a fluorinated ethylene propylene fluoropolymer.
(12) Combination control consists of gasketed plastic enclosure, thermostat, contactor and optional control transformer. Transformer must be used on 480 volts and is recommended for 240 volts. To omit step down transformer, add "LT" to end of model number. See NE20 chart for thermostat options. Longer sensor lengths and additional control options available, consult factory.
FEP is a fluorinated ethylene propylene fluoropolymer.
(12) Combination control consists of gasketed plastic enclosure, thermostat, contactor and optional control transformer. Transformer must be used on 480 volts and is recommended for 240 volts. To omit step- down transformer, add "LT" to end of model number. See DE chart for thermostat options. Longer sensor lengths and additional control options available, consult factory.
FEP is a fluorinated ethylene propylene fluoropolymer.
Longer sensor lengths, thermocouples, 100 ohm RTDs, voltage, current and frequency inputs as well as 4-20 mA outputs available as options, consult factory.
FEP is a fluorinated ethylene propylene fluoropolymer.
(12) Combination control consists of gasketed plastic enclosure, thermostat, contactor and optional control transformer. Transformer must be used on 480 volts and is recommended for 240 volts. To omit step- down transformer, add "LT" to end of model number. See DQ chart for thermostat options. Longer sensor lengths and additional control options available, consult factory.
FEP is a fluorinated ethylene propylene fluoropolymer.